Browse all practice questions for the Kentucky Journeyman Plumbing Practice Test. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Kentucky Journeyman Plumbing Practice Test course image
All questions

These questions are part of the practice quiz. Start practicing

  • If a drain is subject to back flow, it shall be equipped with a _______ _______?
  • __________ or ___________ shall not be used below ground for water lines under a house or building
  • A vent shall rise vertically at an angle to the vertical before offsetting horizontally. What are the required angle and the distance above the served fixture before offsetting?
  • Pedicure chair drains into a ______ ______, and the hot and cold water must have a ______ ______ ______ backflow preventer.
  • The hot and cold water piping shall extend in size to the first fixture branch by what amount?
  • Fixtures other than a WC or a pedestrian urinal shall be provided with what component?
  • Name 4 materials listed as acceptable for a house sewer.
  • To classify as a family dwelling what and how many fixtures must be present?
  • The main water shutoff valve in a house or building shall be _____ _____
  • If a fuel-fired water heater is installed in a closet, what type of door is required?
  • Horizontal steel pipe shall be supported at 8 feet for 1 1/4 inch and smaller and 12 feet for 1/2 inch and larger.
  • For a floor sink installed flush with the floor, which feature is required?
  • Which action requires a permit?
  • Which device is specified as a backflow preventer for the hot and cold water supply to a pedicure chair?
  • DWV system subject to freezing, you can pour RV antifreeze down the traps.
  • Liquid waste shall discharge into a ______ before entering the sewer.
  • For CPVC pipe, support intervals are 3 feet for 1 inch or less and 4 feet for larger pipes.
  • A flushometer must have what device placed above the fixture?
  • How many members are on the state plumbers examining committee?
  • Which list presents four acceptable materials for a house sewer?
  • The distance between cleanouts shall be no longer than how many feet?
  • Shower faucets shall be _______ and ________ balanced
  • The plumbing inspector can stop progress of a construction by issuing a
  • CISPI stands for which of the following?
  • How many days before expiration is the license renewal notice mailed?
  • Which combination of fixtures represents the minimum for classifying as a family dwelling?
  • Homeowners seeking a plumbing permit must be in compliance with which code chapter?
  • Cross connection means any physical connection or arrangement between ___ otherwise separate piping system.
  • A sewer going under a driveway must have how many inches of cover?
  • CPVC threaded adapters shall be permitted.
  • Which of the following is a listed acid waste pipe material?
  • Where should the T&P valve be installed on a water heater?
  • A water closet with a flushometer water line is what size?
  • Which statement about examination papers retention is true?
  • The lavatory faucet maximum flow is...
  • Which statement is true regarding the maximum distance from the branch to the fixture?
  • PEX sizes one inch and smaller installed horizontally shall be supported at intervals not to exceed how many inches?
  • What is the maximum flow rate for a shower head? (alternate wording)
  • Which statement is true about a fixture's overflow according to the rule?
  • PVC stands for which of the following?
  • A house sewer shall be laid on a grade of notes less than _______ and not more than a _______ per foot.
  • For how many minutes shall the DWV system be tested by air and water?
  • Residential water closets shall not exceed how many gallons per flush?
  • CLVC water line joints below ground and under a house or building shall be tested to at least _____ psi
  • Grease traps installed inside buildings must have what features?
  • The smallest water line enclosed in a wall is 1/2 inch.
  • Floors in toilet rooms shall be constructed of ______ ______.
  • The pedicure chair hazard requires backflow protection on which water lines?
  • ABS stands for which of the following?
  • What is the minimum lettering size for the master's license on a plumbing truck?
  • Which backflow device is used with boilers that have chemical feed to prevent contaminants from entering the supply?
  • Before an inspection and test, how many feet of pipe replacement are allowed?
  • Every water heater shall be accessible for which actions?
  • No license shall be issued without passing a test administered by the department for which trade?
  • Push-fit fitting systems are approved for use with which pipe material?
  • Which size is used for a water closet supply line with flushometer?
  • Cast iron no hub bands shall be torqued at _____ inch pounds.
  • CPVC threaded adapters shall not be permitted.
  • ASTM stands for which of the following?
  • An instantaneous water heater must have a properly sized valve to relieve pressure. What type of valve is required, not to exceed 150 pounds?
  • Inspections are not required in replacing _____ plumbing fixtures?
  • AC drain lines must not connect directly to the DWV.
  • Which of the following best describes the recommended action when an inspector issues an order due to noncompliance?
  • What is the protective device that covers the orifice of a drinking fountain?
  • No permanent water supply shall be provided to any building by any public utility or water district where which system has not been installed?
  • What is the term for the depth at which a vacuum breaker will stop preventing backflow?
  • A grease trap used inside shall have a ______ and be _______?
  • What is the maximum flow for a lavatory faucet?
  • For how many years must the examination papers be preserved by the department?
  • CISPI stands for which of the following?
  • When can SDR 35 be used inside a building?
  • Type M copper shall be _________ before passing through concrete floor
  • Before offsetting horizontally, the vent must rise to a point above the served fixture by how many inches?
  • Which of the following represents the maximum allowable flow for a standard shower head?
  • In a combined sewer system, every ______ shall be installed above the cover of the nearest manhole.
  • Horizontal steel pipe shall be supported at _____ foot intervals for 1 1/4 and smaller and ______ foot for 1 1/2 and larger.
  • Under concrete floors, how many inches of grillage must be on the top, bottom, and sides of the pipe?
  • All material and labor necessary for inspections and tests shall be furnished by the person procuring the _______ _______.
  • A plumbing company must carry which type of insurance?
  • Buildings shall have an independent connection with either a ________ or ________ sewer.
  • A 2 inch floor drain can be installed in which location?
  • Permit issuance is limited to which individual?
  • The department may require the production of ______ and other evidence during an inspection.
  • The pan drain for an attic water heater must be connected in a manner similar to which type of drain?
  • Which device provides backflow protection for yard hydrants?
  • Which scenario triggers backflow protection for a pedicure chair?
  • Commercial ejector vent size is _____ inches, but if the ejector pit is within _____ feet of a 3 in vent stack the vent can be _____ inches.
  • Which device provides backflow protection by maintaining a reduced pressure between the supply and the potential backflow?
  • If you bench the water service, the ws at all points must be ____ above the sewer.
  • What is the name of the device that prevents backflow in a drain that may experience back pressure?
  • If a fixture is found usable, its repair, replacement, or removal must be completed within how many days after notice?
  • Flat vent must be approved by the ______ before installing.
  • Each length of pipe, fitting, or device used in plumbing shall be _____ _____ with the quality and maker's name.
  • The water service shall be buried at least 30 inches
  • ________ or __________ shall not be used below ground for water lines
  • The final air test must be maintained for at least how many minutes?
  • What is the maximum number of days a violator can be imprisoned under this chapter?
  • For a water heater installed in a residential attic, the drain pipe must be at least what size?
  • A mechanically formed copper tee is for _____ ground only.
  • In residential dwelling, the shutoff valve shall be placed within _____ _____ of the water heater
  • When benching the water service, the required vertical clearance above the sewer is 18 inches.
  • A water closet or urinal shall be flushed by means of an approved ____ or ____ valve
  • The plumbing permit expires _____ year after date issued if work has not begun.
  • If you hold a plumbing license in another state, is it valid in Kentucky?
  • True or False: If you're taking over a plumbing permit you are responsible for everything the other plumber installed on the permit.
  • Grease traps are installed in which locations?
  • Traps shall not extend nearer to the floor than 12 inches, with an exception for which fixtures?
  • Name the three degrees of hazard connections.
  • Residential washing machines drain pipe extension height above the floor should be what in inches?
  • Which of the following is NOT listed as a kind of acid waste pipe material?
  • Sand traps shall be provided with a ____ inch trap.
  • Boiler with a chemical feed is equipped with what kind of back flow device?
  • Which of the following is NOT typically required for license renewal?
  • All retailers, wholesalers, and installers selling or offering for sale a water heater device shall, within 30 days of the sale forward a list of _____ and _____ of purchasers.
  • What do the three sets of detailed plans and specifications show for the proposed facility?
  • What term completes the phrase: comingling plastic pipe with adapters requires approved ______ fittings.
  • Which list correctly names the three hazard levels for cross connections?
  • What is the minimum size of the water service from the property line to the water heater?
  • A permit refund is made within ______ months and work has ______ _____ on the project.
  • DWV system testing uses which two methods?
  • When installing PEX that is one inch in diameter or smaller in a horizontal run, supports must be placed at intervals no greater than how many inches?
  • What is a common vent?
  • Yard hydrants should have what form of back flow protection?
  • If a dual water distribution system is used, the non potable water system shall be identified in what manner?
  • The toilet room floor material must be non-absorbent.
  • Which worker category is not allowed to construct, install, or alter plumbing unless supervised?
  • Water closet in a unisex public restroom shall have a ________ _______ with a split open front ______.
  • Receiving the discharge from an open receptacle into a septic system must be at least ____ inches above the surface of the ground.
  • A corrosive liquid must pass through ________ before entering the sewer.
  • Storm drain or sewer cannot be layed within how many feet of a wall?
  • The water service shall be buried at least __________ _________
  • No water heating device shall be sold in the Commonwealth unless it has a
  • The statement that best defines a cross-connection is:
  • The T&P waste line pipe shall be within ____ inches from the finished floor
  • Do you need a permit for replacing a house sewer?
  • Not a testing method for the house sewer?
  • Type M copper shall be _________ before passing through ________ floor
  • Residential toilets are limited to what gallons per flush?
  • What is the maximum flow rate permitted for a sink faucet?
  • The department uses _____ basic principles to define the intent for design of the code
  • Sand traps are typically installed in which settings?
  • A sewer shall have atleast _______ inch cover.
  • Any person who violates any provision of this chapter shall be fined not less than _____ dollars nor more than _____ dollars or imprisoned for more than _____ days.
  • Which statement correctly describes when backfilling should occur relative to inspection and testing of the piping?
  • Directional flow fittings and Continuous waste are used in which location?
  • What is the name of the backflow preventor required for the pedicure chair hazard?
  • No person, firm, or corp shall contract, install or alter any plumbing without first having _________ a plumbing inspection
  • The overflow from a fixture shall be what?
  • If more fixtures that receive human waste are installed, the room will need a ______ ______ and a ______ ______.
  • All hose connections shall be equipped with a vacuum breaker, except those intended for what appliance?
  • A water heater installed in a residential attic must have what feature below the unit?
  • If a building is condemned for unsanitary conditions, will it need all new plumbing?
  • Fuel-fired water heater vents shall not be connected to a flue serving a what kind of apparatus?
  • When using a floor sink installed flush with the floor, it must have what?
  • When does a Kentucky plumbing license expire?
  • Should vent piping be pitched so that it would drip back to the soil or waste pipe?
  • If any part is covered before inspection, should it be uncovered?
  • Who are the four attorneys that can represent the department?
  • ASSE stands for which of the following?
  • The maximum permissible distance between cleanouts is how many feet?
  • No more than how many fixtures may be on a 1/2 inch fixture branch?
  • Which statement correctly identifies the use of SDR 35 inside a building?
  • What is the minimum age required to apply for a master or journeyman plumbing license?
  • If location of water heater does not have floor drain, the T&P waste line shall be piped outside of a building with a ____ turned down and piped to within ____ inches of ground
  • ASSE stands for which of the following?
  • Lead solder in plumbing is defined as solders and flux containing which of the following?
  • If the water inlet for a pedicure chair is below the flush level rim, it is treated as which hazard level?
  • Plumbing inspectors shall have at least _____ years experience as a journeyman or master plumber?
  • Do you need a permit for replacing backflow device on the water service?
  • Before backfilling trenches, what must be done to the piping?
  • Do you need a permit for replacing a fixture?
  • ASTM stands for which of the following?
  • Trenches shall be kept ______ until the piping has been ________, _________, and ________.
  • Before entering sewer, corrosive liquids must pass through which process?
  • The level to which the vacuum breaker may be submerged before back flow will occur is the
  • Which distance represents the maximum support spacing for PEX piping 1 inch and smaller when installed horizontally?
  • The number of _____ in the water service is to be kept to a minimum.
  • Horizontal CPVC pipe shall be supported at _____ foot intervals for 1 inch or less and for larger pipe ____ foot intervals.
  • The supply line size for a water closet with a flushometer is which of the following?
  • Which statement best describes supervision for journeyman plumbers?
  • A master plumber is responsible for notifying the department when he or she ______ or ______ connections with a company?
  • Lead shall not be used in the installation or repair of potable systems.
  • A cross connection between a private water supply and a public water supply shall not be made.
  • What is the maximum flow rate permitted for a standard shower head?
  • Do you need a permit for replacing a water heater?
  • Materials shall be equal or ______ to comply with the code.
  • What inch vent is required for the discharge after the separator?
  • Self cleaning flux shall be used in place of cleaning copper pipe.
  • Which of the following is a stated requirement for an applicant for a master or journeyman plumbing license?
  • Which feature can trigger the high hazard classification for a pedicure chair water inlet?
  • All fees shall be payable to the _________ _______ _______ .
  • No person shall use _____ or ______ materials in the working of plumbing
  • The test for potable water supply is no leaks under ______ ______ pressure.
  • Which statement best describes who must notify the department about commencements or severances of connections with a company?
  • Under the described condition, the water inlet is classified as what hazard level?
  • In the pedicure chair hazard, the backflow preventor should be which of the following?
  • Which statement is true about the pedicure chair hazard description?
  • Commercial water closets shall not exceed how many gallons per flush?
  • If a single check valve is installed in a water system, a thermal expansion tank is needed.
  • How many members are on the state plumbers examining committee?
  • Sand traps require a trap size of what inches?
  • Shower pan shall be constructed without a seam and extend to a minimum height of how many inches on all vertical walls?
  • Traps shall not extend nearer to the floor than how many inches, except laundry trays or similar fixtures?
  • AC shall not have any drainpipe directly connected to the DWV. True or False?
  • Who may be issued a plumbing permit?
  • What must an applicant show to renew a Kentucky plumbing license?
  • A pedicure chair hazard requires a backflow preventor on which water lines?
  • If the water inlet for a pedicure chair is below the flush level rim or is equipped with a spray hose, it shall require a backflow preventor on both hot and cold water lines of which type?
  • Can you lay a sanitary tee flat on a sewer?
  • Piping that has been used for another purpose cannot be used for water distribution.
  • What unit is used to specify vent sizes in the plumbing code described?
  • What kind of test will be given by the department?
  • Sand Traps are used in which locations?
  • Who administers the plumber license tests?
  • What is the required support interval for SDR 40 PVC pipe?
  • No person or company shall advertise without a ____ license.
  • On which side of the water heater should the T&P valve be installed?
  • Who has custody of the APML?
  • What torque value (in inch-pounds) is required for cast iron no-hub bands?
  • Which factor is used to determine the total number of plumbing fixtures?
  • In plumbing terminology, DWV stands for which of the following?
  • Which statement about permits is true?
  • Upon cancellation of insurance, insurance carriers shall notify which entity?
  • In a commercial ejector vent system, within how many feet of a 3 inch vent stack can the vent be reduced to 2 inches?
  • Fire protection using water from potable water system shall be equipped with ________ check valves, one of which may be an ________ check valve.
  • What two items must appear on plumbing trucks in not smaller than 3 inch lettering?
  • Who approves the parts and materials list in the code?
  • Which citizenship status is required for a master or journeyman plumbing license applicant?
  • Commercial toilets may not exceed what gallons per flush?
  • The backflow preventor described for the pedicure chair hazard is of which principle?
  • Comingling of plastic pipe shall not be allowed unless approved male or female adapters or other ______ fittings that have been approved.
  • The elongated bowl is specified for which fixture in unisex public restrooms?
  • If a plumbing fixture is found in usable condition, it shall be repaired, replaced, or removed within how many days upon written notice?
  • Which type of sewer connection is acceptable for buildings?
  • Excavation for sewers shall be _______ _______ work.
  • What is the maximum distance from the branch to a fixture?
  • Which backflow preventor type is described for the pedicure chair hazard?
  • The drain that pedicure chairs discharge into is described as an ______ ______.
  • One of the check valves may be an alarm check valve; how many check valves are required overall?
  • Residential ejector vent size is which of the following?
  • A _____ test shall be used in testing the condition of a plumbing fixture?
  • A waste pipe is defined as which of the following?
  • A house sewer shall be laid in how many inches of grillage?
  • Water free from impurities is ___ water.
  • The installer should avoid prolonged breathing of vapors from PVC solvent or cement.
  • If a sewer is not available, the house drain shall be connected to an approved _________ _________ _________.
  • What is the minimum cover required for a sewer?
  • The T&P valve installed on each water heater on the hot water side shall be placed within _____ ____ of the water heater
  • The smallest water line enclosed in a wall is what size?
  • Residential washing machines shall have a trap of what size and how many inches above the floor should the drain be extended?
  • The mechanical protection is a ________.
  • Final air test is equivalent to a _______ inch water column, and it shall be maintained for atleast _______ minutes.
  • A urinal shall not exceed how many gallons per flush?
  • ABS stands for which of the following?
  • The minimum size water service pipe shall be _____ inch.
  • Discharge from an open receptacle into a septic system must be at least how many inches above ground surface?
  • The department has the power to enter premises for purposes including inspections, interrogations, and to require the production of what?
  • The water service shall have piping not less than _____ apart from the sewer.
  • Horizontal copper shall be supported at ____ foot intervals for 1 inch and smaller and ______ foot for 1 1/4 and bigger.
  • A water hammer device is installed as close as possible to the valve causing the problem.
  • Which statement correctly identifies the required furnishing for inspections and tests: All material and labor for inspections and tests shall be furnished by the person procuring the _______ _______.
  • Polybutylene (PEX) have a brass or copper clamping ring.
  • If a dual water distribution system is used, the non potable water system shall be ____ and _____ identified
  • What is the maximum distance from the branch to the fixture?
  • What is the minimum distance required between water service and sewer to prevent contamination?
  • Which statement correctly describes the recommended material quality for plumbing work?
  • DWV stands for which of the following?
  • If a single check valve is installed in a water system, a ________ ______ ______ is needed.
  • Do you need a permit for replacing the water service?
  • The orifice of a drinking fountain shall be protected with a ________
Subscribe

Get the latest from Examzify

You can unsubscribe at any time. Read our privacy policy